Publicación:
Resultados auditivos y de beneficios comunicativos en pacientes tratados con el implante activo de transmisión ósea Bonebridge

dc.contributor.authorGarcía Gómez, Juan Manuel
dc.contributor.authorPeñaranda Sanjuán, Augusto
dc.contributor.authorAparicio, María Leonor
dc.contributor.authorBarón, Clemencia
dc.contributor.authorZamora, Lina
dc.contributor.authorPuerta, Mauricio
dc.contributor.authorMosquera Ortiz, César Augusto
dc.date.accessioned2021-04-23T15:32:00Z
dc.date.available2021-04-23T15:32:00Z
dc.date.issued2014
dc.description.abstractIntroducción: El avance en dispositivos de rehabilitación auditiva ha logrado llegar a los dispositivos de transmisión ósea por medio de anclaje al hueso. El BAHA®(Bone Anchored Hearing Aid, Cochlear Co., Australia) es el más usado, dada su ganancia en el rango de frecuencias altas con menor distorsión de la señal; sin embargo, con complicaciones importantes, como infección, pérdida del implante y necesidad de cirugía revisional, que impactan en calidad de vida y costos. Debido a esto se han desarrollado implantes transcutáneos con menos complicaciones y resultados audiológicos similares, como el nuevo sistema activo de conducción ósea Bonebridge®. Objetivo:Describir los resultados auditivos y beneficios comunicativos del sistema implantable transcutáneo activo de conducción ósea Bonebridge® en hipoacusia conductiva y mixta. Diseño: Estudio pseudoexperimental tipo antes y después. Métodos: Se analizó a los pacientes implantados con el Bonebridge® entre octubre del 2012 y agosto del 2013, por el Servicio de Otología del Hospital Universitario Fundación Santa Fe de Bogotá, y se evaluaron ganancia funcional en audiometría, logoaudiometría, beneficio comunicativo y APHAB pre y posquirúrgico. Resultados: No se encontraron diferencias significativas en la vía ósea pre y postoperatoria. En las pruebas en campo libre solo hubo diferencia en la frecuencia de 500 Hz (P < 0,05). Se evidenció ganancia funcional en la discriminación del lenguaje en bisílabos a 60 dB SPL (nivel de presión sonora) (P: 0,042); se encontraron diferencias en el cuestionario de beneficio comunicativo APHAB (P: 0,043) en todas sus subcategorías, exceptuando aversión (P: 0,068). No hubo complicaciones. Conclusiones: ElBonebridge® es seguro y eficaz para la rehabilitación auditiva.spa
dc.description.abstractIntroduction: Advances in hearing rehabilitation devices have developed bone conduction devices through bone anchorage, BAHA® (Cochlear Bone Anchored Hearing Aid Co., Australia) is the most used because of its profit in the range of higher frequencies with less signal distortion, however, ought to its complications such as infection, implant loss and need for revisional surgery, which impact in costs and quality of life; transcutaneous implants have been developed with fewer complications and similar audiological results as the new active system Bonebridge® bone conduction. Objective: To describe the auditory results and communicative benefits of the active transcutaneous bone conduction implantable system Bonebridge® for treatment of conductive and mixed hearing loss. Desing: Pseudoexperimental before and after study. Methods: Patients who were implanted with Bonebridge® between October 2012 and August 2013 were analized by the Otology Department from the Fundación Santa Fe University Hospital in Bogotá, assessing functional gain in audiometry, speech audiometry and communicative benefit, APHAB, before and after surgery. Results: No significant differences in bone conduction were found before or after surgery. In free field test there was only a significant difference for 500 Hz frequency (P < 0.05), functional gain was observed in speech discrimination at 60 dB SPL disyllabic (P 0.042). There were differences for communicative benefit questionnaire (P 0.043) with the use of the device in every subcategories except aversion (P 0.068). There were no complications. Conclusion: Bonebridge® is safe and effective for hearing rehabilitations.eng
dc.format.extent5 p.spa
dc.format.mimetypeapplication/pdfspa
dc.identifier.urihttps://repositorio.fucsalud.edu.co/handle/001/1461
dc.language.isoengspa
dc.language.isospaspa
dc.publisherAsociación Colombiana de Otorrinolaringología y Cirugía de Cabeza y cuello, Maxilofacial y Estética Facialspa
dc.publisher.placeColombiaspa
dc.relation.citationendpage162spa
dc.relation.citationissue3spa
dc.relation.citationstartpage158spa
dc.relation.citationvolume42spa
dc.relation.ispartofRevista Acta de otorrinolaringología y cirugía de cabeza y cuello ISSN: 0120-8411 Vol. 42 Núm.3 (2014)
dc.relation.ispartofjournalActa de Otorrinolaringología y Cirugía de Cabeza y Cuellospa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)spa
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/spa
dc.sourcehttps://revista.acorl.org.co/index.php/acorl/article/view/145/89spa
dc.subject.proposalPérdida auditivaspa
dc.subject.proposalCorrección de deficiencia auditivaspa
dc.subject.proposalConducción óseaspa
dc.titleResultados auditivos y de beneficios comunicativos en pacientes tratados con el implante activo de transmisión ósea Bonebridgespa
dc.titleHearing results and communication benefits in patients treated with the active bone conduction implant Bonebridgeeng
dc.typeArtículo de revistaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_6501spa
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/articlespa
dc.type.versioninfo:eu-repo/semantics/publishedVersionspa
dspace.entity.typePublication

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Resultados auditivos y de beneficios comunicativos en pacientes tratados con el implante activo de transmisión ósea Bonebridge®.pdf
Tamaño:
244.58 KB
Formato:
Adobe Portable Document Format
Descripción:
Artículo
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
15.06 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones